Sensecap M2
Integration manual
Press the button (at the back, next to the Ethernet connection) for 5 seconds until the blue LED flashes slowly.
The gateway has now created a WLAN. Connect your notebook to the WLAN “SenseCAP_xxxxx”.
The default WLAN password is 12345678
Open the browser on your laptop and enter the following URL in the address bar 192.168.168.1
Log in:
Default user: admin
You can find the default password on the back of the gateway
Select “LoRa” -> “LoRa Network”
Select the “Packet Forwarder” mode
Select the server address “lora-gateway.smart-me.com”
Server Port (Up) and Server Port (Down) is 1700
Click on “Save & Apply”
10. check under “Status” -> “Overview” whether two green check marks are displayed.
11. the gateway should now be displayed as “online” on https://lora.smart-me.com.